Create yourself a spreadsheet with a set of entries for each room. You
need three bits of information to workout the heatloss:
The surface area
The temperature differential
The u value of the surface.
Multiply the lot together to get a figure of watts/hour transferred
through the surface.
(if a wall has a window then subtract the area of the window from that
of the wall, and count the window as a separate surface).
One you know the loss (or gain) through each of the surfaces add them up
to get a nett loss/gain for each room
Lots more info here-
http://www.diydata.com/planning/ch_design/sizing.htm
|
| Peter Taylor replied to John Rumm on 16 May 2004 |
John Rumm wrote
Don't forget the air change factor!
Peter
|
|